MTS Biaxial/Torsion Frame, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Thumb MTS Biaxial/Torsion Frame capable of performing multiaxial static and fatigue experimentation.

ARAMIS Digital Image Correlation System, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Thumb Full field strain field visualization and measurement of materials. System can be used simultaneously with mechanical test frames and thermal chambers.

Allied Variable Speed Diamond Saw, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Thumb The equipment allows sectioning of material specimens under variable speeds (10-500 rpm) in order to reduce the cutting damage on the surface of the sample. This also includes the diamond tipped cutting saw used for cutting composite (and other) specimen.

BET Surface Area and Porosity Analysis - Tristar II 3020, Facility:CLAS Goldwater Environmental Laboratory

Thumb The Tristar II 3020 provides high-quality surface area and porosity measurements on solid materials by using the technique of gas adsorption. The TriStar II is a fully automated, three-station analyzer capable of increasing the speed and efficiency of quality control analyses, with the accuracy, resolution, and data reduction to meet most research needs. SEE MATERIAL REQUIREMENTS BELOW

Bruker Avance III HD 850 MHz NMR, Facility:CLAS Magnetic Resonance Research Center

Thumb The Bruker 850 MHz spectrometer is equipped with a 5 mm H&F-C/N-D TCI Cryoprobe, a 1.7 mm H-C/N-D TCI Cryoprobe, and 1.3 mm Ultrafast HX MAS probe. This instrument is equipped for liquids and solids. The instrument is ideally suited for the study of complex biomolecules.

CHN Elemental Analysis - PE2400, Facility:CLAS Goldwater Environmental Laboratory

Thumb The PE 2400 is a conventional elemental analyzer. It operates by flash combustion of the specimen encapsulated in tin cups or disks whereby the specimen is completely combusted at a temperature of 1760 C. The resulting gases are chemically scrubbed of the halogens (and of sulfur in the CHN mode) and are separated in a GC column. Detection is conducted by a thermal conductivity detector (TCD). Total C, H, and N are calculated with a precision of 0.1g. Element ratios are more significant since they minimize instrument error. Molar element ratios may be reliably reported for up to three decimal places.

Custom Software Development, Facility:Computational and Experimental Mechanics Laboratory

Developing C++/FORTRAN/MATLAB code to carry out engineering analysis

Environmental Chamber, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Hot/cold conditioning with humidity control

Finite Element Analysis, Facility:Computational and Experimental Mechanics Laboratory

Implicit and explicit linear, nonlinear multiphysics finite element analysis of engineering components and systems

Gaertner-Stokes Ellipsometer, Facility:Biodesign Biosurface Chemistry Facility

Thumb Can be used for measurements of surface and thin films on Silicon wafers or Gold Chips.

Heated Fabrication Press, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Thumb Equipment used for fabrication of composite plates.

High Speed Data Acquistion/Wave Generation, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Thumb NI PXI chassis with high speed digitizer, multiplexer, and arbitrary waveform generator.

Isotemp Oven, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Oven capable of pulling a vacuum

Kruss Easy Drop Contact Angle, Facility:Biodesign Biosurface Chemistry Facility

Thumb Surface chemistry measurements. Hydrophobic/Hydrophilic surface studies.

Mechanical Testing, Facility:Computational and Experimental Mechanics Laboratory

Testing to determine properties of materials or systems

Multi-anvil high pressure apparatus: Big Blue, Facility:CLAS High Pressure Facility

Thumb The Big Blue multi-anvil is for higher pressure experiments, reaching a force of 1000 tons. Research on Big Blue usually focuses on the force range from 300 to 1000 tons; forces below 300 tons may be reached on the smaller Green multi-anvil.

Multi-anvil high pressure apparatus: Green, Facility:CLAS High Pressure Facility

Thumb The green multi-anvil is limited to experiments below 300 tons.

NanoSIMS 50L @ ASU, Facility:NanoSIMS Facility

Thumb The Cameca Ametek NanoSIMS 50L is a unique ion microprobe optimizing SIMS analysis performance at high lateral resolution. It is based on a coaxial optical design of the ion gun and the secondary ion extraction, and on an original magnetic sector mass analyzer with multicollection.

Piston Cylinder: Daisy (13 mm), Facility:CLAS High Pressure Facility

Thumb The piston-cylinder Daisy is from the original Holloway lab! It currently features a 13 mm core and can be used to pressures of 2 GPa and 1200 C with sample diameters of 5 mm.

Piston Cylinder: Rusty (19 mm), Facility:CLAS High Pressure Facility

Thumb This PC has a larger diameter core than Daisy, and can reach 1 GPa and 1200 degrees C with sample size of 5 mm and larger.

Static/Quasistatic Mechanical Testing, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Thumb Tension, compression, shear tests on electromechanical frame. The equipment's maximum loading capacity is 250 kN and it has a removable thermal chamber.

Struers LaboPol 5 Polisher, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Thumb Grinding and polishing of material samples in preparation for microscopy. The equipment is able to control the force applied, fluid rate dispensed, and platen speed (50 - 500 rpm).

Test Data Analysis, Facility:Computational and Experimental Mechanics Laboratory

Analysis of test data to create components of constitutive model

Thermo Nicolet 6700 FTIR and Continuum Microscope System, Facility:Biodesign Biosurface Chemistry Facility

Thumb Used for infared sample analysis.FTIR Bench Accessories: Smart Orbit, Smart SAGA, Smart ARK, GATR, TransmissionFTIR Bench Accessory Applications:LiquidsSolidsSemi-solidsPowdersQuantitative and qualitative measurementsPolymer films, packagingFTIR Microscope Accessories: Grazing Angle, ATR-tip, %Reflectance, %TransmittanceMicroscope ATR-tip Applications• Surface analysis/depth profiling• Coatings on non-reflecting substrates• Inclusions in resins, polymers and rubber materials• Microelectronics• Forensics• Defect analysis• Residuals inside depressionsMicroscope Grazing Angle Applications:• Contaminants on reflective surfaces• Lubricants on hard disks• Coating imperfections on metallic surfaces

VNMRS 400 MHz WB NMR , Facility:CLAS Magnetic Resonance Research Center

Thumb The VNMRS 400 WB is a dedicated solid state NMR instrument. It is equipped with triple resonance MAS probes in sample sizes from 4mm to 2.5mm. As a result MAS speeds up to 35 kHz are possible.

VNMRS 800 MHz NMR, Facility:CLAS Magnetic Resonance Research Center

Thumb The VNMRS 800 MHz spectrometer is capable for liquids, solids, or MRI experiments. The instrument is ideally suited for the study of complex biomolecules.

Zeiss LSM 700 Confocal Microscope, Facility:Adaptive Intelligent Materials & Systems (AIMS) Center

Thumb Microstructural analysis of material samples. The equipment consists of two laser channels (405 nm and 488 nm) and is also capable of performing optical microscopy using fluorescent, bright field, and dark field settings. The included camera and image analysis software can record images, perform image refinement, and measure microscopic features.